SEQ
  • Bienvenido a la SEQ
    • Junta Directiva
    • Misión, visión y valores
    • Elecciones para la renovación Junta Directiva de la SEQ 2021
    • Estatutos SEQ
    • Colaboradores
    • Hazte socio
    • Contacto
  • Noticias
    • Cursos
    • Agenda de Congresos
    • Sociedades Científicas
    • Revistas Científicas
  • Actividades
    • Reuniones
    • Congresos
    • Cursos de Formación
  • Revista Española de Quimiopterapia
    • Journal info
    • Advance articles
    • Search an issue
    • Submission guidelines
    • Submit a manuscript
  • Documentos
    • Documentos de Consenso
    • Libros y monografías
    • Revista Infección y Vacunas
    • Informes
    • Declaraciones
    • Base de Datos
    • Otros
      • Curiosidades
      • Narraciones Infecciosas
  • Click to open the search input field Click to open the search input field Buscar
  • Menú Menú
Abstract 2013

Rev Esp Quimioter 2013:26(2):116-118

Accuracy of Etest method to study Campylobacter spp. susceptibility to erythromycin, ciprofloxacin and tetracycline                                
 

NURIA SANZ-RODRÍGUEZ, MARÍA TERESA PÉREZ-POMATA, OLHA STELMAKH, DAVID PÉREZ-BOTO, JOSÉ LUIS GÓMEZ-GARCÉS             

Introduction. In industrialized countries Campylobacter jejuni is the enteropathogen most frequently isolated from the feces of patients with gastroenteritis. The Etest accuracy to categorize Campylobacter spp. susceptibility to erythromycin, ciprofloxacin and tetracycline was evaluated.
Methods. Ninety strains were studied. The Etest® was performed following the manufacturer’s instructions on commercial plates of Mueller-Hinton blood. The breakpoints were those recommended by the Clinical Laboratory Standards Institute (CLSI) for broth microdilution. The gold standard was the broth microdilution method as recommended by CLSI.
Results. The Etest agreement with the reference method was 100%, 97% and 98% for erythromycin, ciprofloxacin and tetracycline, respectively. No major or very major errors were found.
Conclusions. The Etest results are equivalent to those obtained using the gold standard. The Etest is a valid method to determine susceptibility to tetracycline. It is also a suitable method to categorize strains classified as non-resistant to erythromycin and ciprofloxacin by the diffusion method.

Rev Esp Quimioter 2013:26(2):116-118 [pdf]

11 diciembre, 2009/por csanchez
Compartir esta entrada
  • Compartir en Facebook
  • Compartir en X
  • Compartir en LinkedIn
  • Compartir por correo
https://seq.es/wp-content/uploads/2017/10/LOGO-SEQ-800X400.png 0 0 csanchez https://seq.es/wp-content/uploads/2017/10/LOGO-SEQ-800X400.png csanchez2009-12-11 16:16:362009-12-11 16:16:36Rev Esp Quimioter 2013:26(2):116-118

REVISTA ESPAÑOLA DE QUIMIOTERAPIA

  • Journal Info
  • Advance Articles
  • Issues
  • Submission guidelines
  • Submit a manuscript

Contacto

Telf.: 913 94 15 12
Email: [email protected]

Política de privacidad

Aviso Legal
Política de Privacidad
Política de Cookies

Tweets by TwitterDev
© Copyright - Sociedad Española de Quimioterapia - Enfold Theme by Kriesi
  • Link to Facebook
  • Link to X
  • Link to LinkedIn
Link to: Rev Esp Quimioter 2013:26(2):116-118 Link to: Rev Esp Quimioter 2013:26(2):116-118 Rev Esp Quimioter 2013:26(2):116-118 Link to: Rev Esp Quimioter 2013:26(2):119-127 Link to: Rev Esp Quimioter 2013:26(2):119-127 Rev Esp Quimioter 2013:26(2):119-127
Desplazarse hacia arriba Desplazarse hacia arriba Desplazarse hacia arriba