SEQ
  • Bienvenido a la SEQ
    • Junta Directiva
    • Misión, visión y valores
    • Elecciones para la renovación Junta Directiva de la SEQ 2021
    • Estatutos SEQ
    • Colaboradores
    • Hazte socio
    • Contacto
  • Noticias
    • Cursos
    • Agenda de Congresos
    • Sociedades Científicas
    • Revistas Científicas
  • Actividades
    • Reuniones
    • Congresos
    • Cursos de Formación
  • Revista Española de Quimiopterapia
    • Journal info
    • Advance articles
    • Search an issue
    • Submission guidelines
    • Submit a manuscript
  • Documentos
    • Documentos de Consenso
    • Libros y monografías
    • Revista Infección y Vacunas
    • Informes
    • Declaraciones
    • Base de Datos
    • Otros
      • Curiosidades
      • Narraciones Infecciosas
  • Click to open the search input field Click to open the search input field Buscar
  • Menú Menú
Abstract, Abstract 2022

Rev Esp Quimioter 2022; 35(2):165-170

Sonication did not provide reliability to Maki technique for catheter related bloodstream infection diagnosis

LEONARDO LORENTE, MARÍA LECUONA, ALEJANDRA PÉREZ-LLOMBET, ADRIANA GONZÁLEZ-MESA, MANUEL CALLEJÓN, TERESA DELGADO MELIAN, INÉS OLAYA GARCIA, ALEJANDRO JIMÉNEZ, MARÍA LUISA MORA, ANA MADUEÑO

Published: 17 January 2022

http://www.doi.org/10.37201/req/110.2021

Objective. The aim of our study was to analyze sonication and Maki techniques for diagnosis of catheter tip colonization and catheter-related bloodstream infection (CRBSI) on patients admitted to ICU.
Material and methods. Observational and prospective study in one Intensive Care Unit. Patients with some central venous catheter (CVC) at least for 7 days and catheter-related infection (CRI) suspicion (new episode of fever or sepsis) were included. We performed Maki technique followed by sonication of catheter tip. We compared area under the curve (AUC) of Maki, sonication, and techniques combination to diagnosis catheter tip colonization and CRBSI.
Results. We included 94 CVC from 87 CRI suspicion episodes. We found 14 cases of catheter tip colonization and 10 cases of CRBSI. Of the 14 catheter tip colonization cases, 7 (50.0%) were detected by Maki and sonication techniques, 6 (42.9%) were detected only by Maki technique, and 1 (7.1%) was detected only by sonication technique. Of the 10 CRBSI, 6 (60.0%) were detected by Maki and sonication techniques, 4 (40.0%) were detected only by Maki technique, and any only by sonication technique. We found higher AUC in Maki technique than in sonication technique to diagnosis of CRBSI (p=0.02) and to diagnosis of catheter tip colonization (p=0.03). No significant differences were found in AUC between Maki technique and combination techniques for diagnosis of catheter tip colonization (p=0.32) and of CRBSI (p=0.32).
Conclusion. Sonication did not provide reliability to Maki technique for diagnosis of catheter tip colonization and CRBSI.

Rev Esp Quimioter 2022; 35(2):165-170 [Full-text PDF]


16 enero, 2022/por Luis Alou
Compartir esta entrada
  • Compartir en Facebook
  • Compartir en X
  • Compartir en LinkedIn
  • Compartir por correo
https://seq.es/wp-content/uploads/2017/10/LOGO-SEQ-800X400.png 0 0 Luis Alou https://seq.es/wp-content/uploads/2017/10/LOGO-SEQ-800X400.png Luis Alou2022-01-16 18:24:042022-03-13 08:28:13Rev Esp Quimioter 2022; 35(2):165-170

REVISTA ESPAÑOLA DE QUIMIOTERAPIA

  • Journal Info
  • Advance Articles
  • Issues
  • Submission guidelines
  • Submit a manuscript

Contacto

Telf.: 913 94 15 12
Email: [email protected]

Política de privacidad

Aviso Legal
Política de Privacidad
Política de Cookies

Tweets by TwitterDev
© Copyright - Sociedad Española de Quimioterapia - Enfold Theme by Kriesi
  • Link to Facebook
  • Link to X
  • Link to LinkedIn
Link to: Rev Esp Quimioter 2022; 35(2):165-170 Link to: Rev Esp Quimioter 2022; 35(2):165-170 Rev Esp Quimioter 2022; 35(2):165-170 Link to: Rev Esp Quimioter 2022; 35(1):16-29 Link to: Rev Esp Quimioter 2022; 35(1):16-29 Rev Esp Quimioter 2022; 35(1):16-29
Desplazarse hacia arriba Desplazarse hacia arriba Desplazarse hacia arriba

Utilizamos cookies propias y de terceros para garantizar el funcionamiento de la web, medir su uso y mejorar nuestros servicios. Puede aceptar todas las cookies, rechazar las no necesarias o configurar sus preferencias. Política de cookies

Configurar cookies

Necesarias para que la web funcione correctamente. No se pueden desactivar desde este panel.

Ayudan a medir el uso del sitio y mejorar sus contenidos.

Permiten publicidad, medición de campañas o personalización de anuncios.

Guardan preferencias o permiten contenido externo no necesario.